

ModuLaser® Air Sampling Smoke Detection by the Kidde Global Solutions company
High-Sensitivity Smoke Detection for Early Fire Identification
ModuLaser® Air Sampling Smoke Detection provides continuous, high-sensitivity smoke detection for environments where the earliest possible warning of fire conditions is critical.
Using aspirating detection technology, ModuLaser® systems actively draw air samples through a network of pipes and sampling points and analyze them for the presence of smoke particles. This approach enables detection of incipient fires at a much earlier stage than conventional point detectors—often before visible smoke is present.
Designed to integrate with KiddeFenwal detection and control platforms, ModuLaser® Air Sampling Smoke Detection delivers enhanced protection for mission-critical, high-value, and special hazard environments.
Key Advantages
- High-Sensitivity Smoke Detection
Continuously samples air to detect very low concentrations of smoke, enabling early identification of developing fire conditions. - Early Warning at the Incipient Stage
Capable of identifying fires in their earliest phases—often before traditional detectors respond—supporting faster intervention and reduced potential damage. - Continuous Air Sampling
Actively monitors protected areas through a dedicated pipe network, providing consistent coverage even in challenging airflow environments.
- Relative or Adaptive Sensitivity (R) using ClassiFire enhances Nuisance Alarm Rejection
Continuously adjusts sensitivity within UL window to cancel out background obscuration and reject false positives - Flexible System Design
Sampling pipe networks can be tailored to suit large spaces, concealed areas, or locations where point detectors are impractical. - Seamless System Integration
Designed for integration with KiddeFenwal detection and control platforms, supporting coordinated system response and centralized monitoring.
Applications
ModuLaser® Air Sampling Smoke Detection is ideal for environments requiring the highest level of early fire detection, including:
- Data centers and server rooms
- Telecommunications facilities
- Clean rooms and controlled environments
- Archives, libraries, and records storage
- Museums and cultural institutions
- Mission-critical infrastructure and high-value assets

System Architecture
Advanced Detection Architecture
Detection Method
- Active air sampling through a network of pipes and sampling points
- Continuous analysis of air samples for smoke particles
- Multi-level alarm thresholds support early warning and escalating response
System Integration
- Interfaces with KiddeFenwal detection and suppression control platforms
- Supports coordinated alarm, notification, and suppression strategies
- Enables centralized event annunciation and system monitoring
Installation & System Design
- Sampling pipe networks designed to match room layout, airflow patterns, and risk profile
- Detectors installed in accessible locations for simplified maintenance
- Supports protection of open areas, concealed spaces, and high-airflow environments
- Designed for long-term reliability and consistent performance
Technical Specifications
| SPECIFICATION | DETAILS |
|---|---|
| Device Type | Air sampling smoke detection system |
| Detection Method | High-sensitivity aspirating smoke detection |
| Monitoring | Continuous air sampling |
| Sensitivity | Very early smoke detection (incipient stage) |
| Integration | KiddeFenwal detection & control platforms |
| Typical Environments | Mission-critical and high-value spaces |
Compliance & System Standards
- Designed for use within UL-listed KiddeFenwal detection and control systems
- Intended for installation in systems engineered to comply with NFPA 72 and applicable local codes, when installed per system design and AHJ requirements
- UL 268, 7th Edition
Technical Documents
- Kidde Fire Systems ModuLaser® Aspirating Smoke DetectorsDownload PDF
Data Sheet · 696 KB
- KiddeFenwal Senator-25 Aspirating Smoke DetectorDownload PDF
Data Sheet · 280 KB
- Kidde Spec ECS-500 Fluoro-K ARIES-SLX ModuLaser 2023Download PDF
A&E Specs · 79 KB
- Kidde Spec ADS Fluoro-K ARIES-SLX ModuLaser 2023Download PDF
A&E Specs · 282 KB
- Kidde Spec ADS Fluoro-K ARIES-MLX ModuLaser 2023Download PDF
A&E Specs · 361 KB
- KF One Stop Solution Sell Sheet SSK-OSSDownload PDF
Sell Sheet · 1.8 MB
- KF Capabilities BrochureDownload PDF
Brochures · 5.5 MB
Earliest Detection. Greater Confidence.
ModuLaser® Air Sampling Smoke Detection provides the earliest possible indication of fire conditions—helping protect critical assets, minimize disruption, and support informed response when every second counts.
Frequently asked questions
Where can I buy genuine ModuLaser® Air Sampling in Vietnam?
ModuLaser® Air Sampling is supplied in Vietnam by KiddeFenwal Vietnam with technical documentation, certificates and engineering support. Send a quotation request for a project-specific proposal.
Is original technical documentation available for ModuLaser® Air Sampling?
Yes. Data sheets, design–installation–maintenance manuals and listings are in the Document Library; final specifications follow the latest KiddeFenwal data sheet.
How are price and lead time determined?
Fire protection systems are configured per project (protected area, standards, accessories), so pricing and lead time are quoted individually after the KiddeFenwal Vietnam engineering team reviews your requirements.
Need advice or a quote for this product?
KiddeFenwal Vietnam brings the full Kidde Fire Systems, Fenwal Controls and Kidde Fire Protection portfolio – fire detection, suppression and safety controls – to critical industries in Vietnam.